RFP QuestBeta
Awarded · ResultStage · contract

Diamond Light Source Ltd

Two Horizontally Deflecting Double Crystal Monochromators for Beamline K11

Medical Equipment & PharmaCPV 33111000
ValueValue not published
Awarded10 Jul 2017
Published18 Sept 2017
RegionNationwide
Outcome — awarded

This is a contract result notice, not an open opportunity. Details from the official award data.

The brief

This tender is for the design, manufacture, supply and installation of 2 identical, horizontally deflecting, Double Crystal Monochromators (DCM) for use at DLS.

It should be noted that these monochromators deviate from the standard fixed exit Monos in that the exit beam offset varies with energy.

Each monochromator system should include liquid Nitrogen cryogenic cooling and 1 crystal set.

All motors, encoders and limits should be included.

The tender document gives detailed technical specifications for the DCM system, guided by the properties of the source and assessment of available technology.

The DCM s must have a complete cryogenic cooling system and cryo-cooling unit.

However, the Supplier may quote the cryo-cooling unit and distribution circuit as an option.

If the Supplier chooses to do so, the cryo-cooling unit should be quoted as a separate item in the bid.

The 2 cryo-cooling units may be sourced from a third party.

If the Supplier chooses not to do so, each DCM must still be manufactured with all components (coolant pipes, connections etc.,) necessary for cryo-cooling the crystals once a separately procured cryo-cooling unit is connected.

Key requirements

What the supplier must deliver

01

This tender is for the design, manufacture

This tender is for the design, manufacture, supply and installation of 2 identical, horizontally deflecting, Double Crystal Monochromators (DCM) for use at DLS.

02

It should be noted that these monochromators

It should be noted that these monochromators deviate from the standard fixed exit Monos in that the exit beam offset varies with energy.

03

Each monochromator system should include liquid Nitrogen

Each monochromator system should include liquid Nitrogen cryogenic cooling and 1 crystal set.

04

All motors, encoders and limits should

All motors, encoders and limits should be included.

05

The DCM s must have a complete

The DCM s must have a complete cryogenic cooling system and cryo-cooling unit.

Derived from the notice text — always confirm against the original documents.

Buyer intelligence

Make the case to bid

Reveal who to approach at Diamond Light Source Ltd, and generate a go-to-market strategy from their news, accounts and people.

Source & provenance
OCID
aca6f927-3a8d-4d47-a3c8-bcb60275323e
Stage
contract · Contract
Source
Contracts Finder
Buyer ref
DLSITT0394
View the original notice on Contracts Finder

Contains public sector information licensed under the Open Government Licence v3.0. Source data © Crown copyright.

Market context

Who wins this kind of work

The suppliers and buyers around this opportunity — drawn from official award data. Drag to orbit; click a node to explore.

Top suppliers & buyers in Medical Equipment & Pharmaceuticals

Scroll to explore the market network

Diamond Light Source Ltd’s tender network

Assembling the network…