National Oceanography Centre

Shared Area Single and Double Fire Doors Replacement

ValueValue not published
Deadline
Published8 Jul 2026
RegionNationwide
Match for your company
Sign up free to see how well this tender matches your company — the score, the signals that align, and where the gaps are.
The brief

The National Oceanography Centre requires the supply and installation of replacement FD60-rated fire doors and associated door sets within the main stairwell areas of its building as part of a phased fire safety improvement programme.

This procurement relates to Phase 1 of the works and includes the replacement of approximately 35-40 existing fire doors that have reached the end of their service life and no longer meet current fire safety standards.

The contractor shall provide a complete design-compliant door set solution, including the removal and disposal of existing doors and frames, and the supply and installation of new certified FD60 fire door assemblies.

Each door set shall comprise the door leaf, frame, intumescent and smoke seals, glazing (where required), ironmongery, signage, and self-closing mechanisms.

All components must be tested and certified as a complete assembly.

The…

Key requirements

What the supplier must deliver

01

The National Oceanography Centre requires the supply

The National Oceanography Centre requires the supply and installation of replacement FD60-rated fire doors and associated door sets within the main stairwell areas of its building as part of a phased fire safety improvement programme.

02

The contractor shall provide a complete design-compliant

The contractor shall provide a complete design-compliant door set solution, including the removal and disposal of existing doors and frames, and the supply and installation of new certified FD60 fire door assemblies.

03

Each door set shall comprise the door

Each door set shall comprise the door leaf, frame, intumescent and smoke seals, glazing (where required), ironmongery, signage, and self-closing mechanisms.

04

All components must be tested and certified

All components must be tested and certified as a complete assembly.

05

The works shall comply with all relevant

The works shall comply with all relevant fire safety legislation and standards, including BS 476-22 or BS EN 1634-1, with third-party certification from an approved scheme such as Certifire or BM TRADA Q-Mark.

Derived from the notice text — always confirm against the original documents.

Source & provenance
OCID
ocds-h6vhtk-06c683
Stage
award · Awarded
Source
Find a Tender
Buyer ref
064264-2026
View the original notice on Find a Tender

Contains public sector information licensed under the Open Government Licence v3.0. Source data © Crown copyright.

Market context

Who wins this kind of work

The suppliers and buyers around this opportunity — drawn from official award data. Drag to orbit; click a node to explore.

National Oceanography Centre’s tender network

Assembling the network…